This thermocouple electromotive force is too little in room temperature to use compensation lead in the measurement, can ignore the influence of reference terminal temperature changing. The double platinum rhodium’s long-term use temperature is 1600℃, short-term use temperature is 1800℃.Platinum and rhodium6’melting point is 1820℃,which can restrain machine use the upper temperature limit. And the high sensitivity of the display instrument should be equipped due to the little electromotive force rate of the double platinum and rhodium thermocouple. B type thermocouple can be used in oxidation and neutral atmosphere as well as in vacuum environment for short time. B type thermocouple’s life is 10-20 times longer than R S type thermocouple even in reducing atmosphere. Owing to the R﹠S type thermocouple positive to negative diffusion phenomenon will occur in high temperature, and causing thermocouple deterioration.. To prevent the occurrence of these phenomena, add rhodium in platinum to make platinum and rhodium alloy, which can no only improve heat resistance but also enhance thermoelectric power rate of alloy to platinum. The electromotive force of platinum and rhodium alloy to platinum will increase sharply when the rhodium content is less than 20%, once exceeds this value and with the increase of the rhodium content, electromotive force change little,  the thermocouple harden significantly and process difficulty .Therefore the rhodium content of this series alloy couldn’t  exceed 40%(weight ratio).#p#副标题#e# The tendency of Platinum and rhodium alloy is little than pure platinum crystal length, and decrease with increase of platinum, can make the thermoelectric performance more stable and  the mechanical strength higher. Therefore double platinum and rhodium thermocouple has been widely used in 1800 degree heat measurements. Thermocouple indexing no of thermocouple used to be LL-2, now is B. Platinum and rhodium 30-platium and rhodium 6 thermocouple indexing table (indexing No: B) (Reference terminal temperature: 0°C) thermoelectric power: mvcuAZhengzhou Protech Technology Co., Ltd
    0°C 10°C 20°C 30°C 40°C 50°C 60°C 70°C 80°C 90°C  
    0 -0.002 -0.003 0.002 0 0.002 0.006 0.11 0.017 0.025  
  100°C 0.033 0.043 0.053 0.065 0.078 0.092 0.107 0.123 0.14 0.159  
  200°C 0.178 0.199 0.22 0.243 0.266 0.291 0.317 0.344 0.372 0.401  
  300°C 0.431 0.462 0.494 0.527 0.516 0.596 0.632 0.669 0.707 0.746  
  400°C 0.786 0.827 0.87 0.913 0.957 1.002 1.048 ?1.095 1.143 1.192  
  500°C 1.241 1.292 1.344 1.397 1.45 1.505 1.56 1.617 1.674 1.732  
  600°C 1.791 1.851 1.912 1.974 2.036 2.1 2.164 2.23 2.296 2.363  
  700°C 2.43 2.499 2.569 2.639 2.71 2.782 2.855 2.928 3.003 3.078  
  800°C 3.154 3.231 3.308 3.387 3.466 3.546 2.626 3.708 3.79 3.873  
  900°C 3.957 4.041 4.126 4.212 4.298 4.386 4.474 4.562 4.652 4.742  
  1000°C 4.833 4.924 5.016 5.109 5.202 5.2997 5.391 5.487 5.583 5.68  
  1100°C 5.777 5.875 5.973 6.073 6.172 6.273 6.374 6.475 6.577 6.68  
  1200°C 6.783 6.887 6.991 7.096 7.202 7.038 7.414 7.521 7.628 7.736  
  1300°C 7.845 7.953 8.063 8.172 8.283 8393 8.504 8.616 8.727 8.839  
  1400°C 8.952 9.065 9.178 9.291 9.405 9.519 9.634 9.748 9.863 9.979  
  1500°C 10.094 10.21 10.325 10.441 10.588 10.674 10.79 10.907 11.024 11.141  
  1600°C 11.257 11.374 11.491 11.608 11.725 11.842 11.959 12.076 12.193 12.31  
  1700°C 12.426 12.543 12.659 12.776 12.892 13.008 13.124 13.239 13.354 13.47  
  1800°C 13.585 13.699 13.814 — — — — — — —  
cuAZhengzhou Protech Technology Co., Ltd

HOT PRODUCTS

  • Continuous feeding and discharging multi temperature zone large diameter rotary furnace
  • Tube type vertical lifting bell cover furnace
  • 1200 ℃ touch screen high-temperature vacuum tube furnace
  • Large vertical tube furnace with preheating

Inquiry

Please leave a message here. We will reply you in 24 hours.

live chat customer service