Zhengzhou Protech Technology Co., Ltd
phone +8617719806024
email info@lab-furnace.com
Zhengzhou Protech Technology Co., Ltd
about us
Home > Technical Articles

PRODUCT MENU

Technical Articles

Laboratory chemical vapor deposition PECVD electric furnace

Time:2025-07-31 10:20:35

The chemical vapor deposition (PECVD) electric furnace used in laboratories is a commonly used heat treatment coating equipment, which is highly favored by many university laboratories and industrial and mining enterprise laboratories. So, what are the characteristics and application fields of PECVD experimental electric furnaces? Let's take a detailed look below!lFBZhengzhou Protech Technology Co., Ltd

The commonly used slide chemical vapor deposition PECVD electric furnace in the laboratory (click on the image to view product details)lFBZhengzhou Protech Technology Co., Ltd
The commonly used slide chemical vapor deposition PECVD electric furnace in the laboratory (click on the image to view product details)
lFBZhengzhou Protech Technology Co., Ltd

1. Core principles and advantages of equipmentlFBZhengzhou Protech Technology Co., Ltd
PECVD (Plasma Enhanced Chemical Vapor Deposition) electric furnace generates plasma through glow discharge, which activates gaseous precursors (such as SiH ₄, NH3) into highly active ions or radicals, and achieves thin film deposition at low temperatures (400-500 ℃). Its core advantages include:lFBZhengzhou Protech Technology Co., Ltd
Low temperature process: avoids thermal damage to the substrate material caused by high temperature, suitable for flexible substrates (such as polyimide) and thin silicon wafers.lFBZhengzhou Protech Technology Co., Ltd
Efficient deposition: Radio frequency glow technology generates high-density plasma with a higher deposition rate, far exceeding traditional CVD.lFBZhengzhou Protech Technology Co., Ltd
Good film quality: By using plasma bombardment to reduce pinholes and cracks, the uniformity of film formation is high, meeting the needs of large-scale production.lFBZhengzhou Protech Technology Co., Ltd
Material diversity: It can deposit various dielectric films such as SiO ₂, Si ∝ N ₄, Al ₂ O ∝, etc., supporting complex structural designs such as stacked batteries and back passivation batteries.
lFBZhengzhou Protech Technology Co., Ltd

2. Key technical parameters of laboratory equipmentlFBZhengzhou Protech Technology Co., Ltd
Working temperature: Room temperature -1200 ℃ (single/multi temperature zone), suitable for different material deposition requirements (such as SiN ₓ requires 400-500 ℃).lFBZhengzhou Protech Technology Co., Ltd
Temperature control accuracy: ± 1 ℃, ensuring the stability of film growth conditions.lFBZhengzhou Protech Technology Co., Ltd
Vacuum system: molecular pump+mechanical pump combination, maximum vacuum ≤ 10 ⁻ ³ Pa, reduces impurity pollution, and improves film purity.lFBZhengzhou Protech Technology Co., Ltd
RF power supply: accurately control plasma density and optimize film performance.lFBZhengzhou Protech Technology Co., Ltd
Gas system: 1-6 mass flow meters (MFCs), supporting gas mixing and achieving deposition of complex component thin films (such as SiN ₓ/SiO ₂ stack).lFBZhengzhou Protech Technology Co., Ltd
Pressure control: Switching between positive and low pressure to adapt to different process requirements (such as low pressure deposition to reduce defects).lFBZhengzhou Protech Technology Co., Ltd
Intelligent monitoring: over temperature alarm, over-current protection, disconnection prompt, ensuring safe operation of equipment and reducing experimental risks.
lFBZhengzhou Protech Technology Co., Ltd

3. Laboratory Equipment Selection GuidelFBZhengzhou Protech Technology Co., Ltd
Sedimentation rate and efficiencylFBZhengzhou Protech Technology Co., Ltd
Priority should be given to devices with adjustable RF power, supporting low-power startup (to avoid damaging the substrate) and high-power rapid deposition.lFBZhengzhou Protech Technology Co., Ltd
Example: When depositing SiN ₓ anti reflection film in the photovoltaic industry using a tubular PECVD electric furnace, the deposition rate is higher, meeting the demand for higher output.lFBZhengzhou Protech Technology Co., Ltd
Uniformity control of thin filmlFBZhengzhou Protech Technology Co., Ltd
Choose equipment with multi-point RF feeding and uniform air path distribution to ensure better uniformity of film thickness.lFBZhengzhou Protech Technology Co., Ltd
Case: A certain university laboratory adopts rotary tubular PECVD to eliminate the problem of uneven plasma distribution and improve the uniformity of the film through substrate rotation.lFBZhengzhou Protech Technology Co., Ltd
Multi gas path and process compatibilitylFBZhengzhou Protech Technology Co., Ltd
Support at least 2 gas mixtures (such as SiH ₄, NH ∝, N ₂ Ar), To deposit thin films with complex components.lFBZhengzhou Protech Technology Co., Ltd
Extension function: Some devices support the combination of ALD technology to achieve multi-layer structure.lFBZhengzhou Protech Technology Co., Ltd
Safety and Environmental DesignlFBZhengzhou Protech Technology Co., Ltd
Essential functions: Over temperature protection, leakage protection, vacuum pump oil filtration system (reducing volatile organic compound emissions).lFBZhengzhou Protech Technology Co., Ltd
Recommendation: Choose environmentally certified equipment that conforms to the trend of green manufacturing in the laboratory.lFBZhengzhou Protech Technology Co., Ltd
After sales service and costlFBZhengzhou Protech Technology Co., Ltd
Maintenance cycle: It is recommended to replace the vacuum pump oil and inspect vulnerable components such as seals every 3 months.lFBZhengzhou Protech Technology Co., Ltd
Supplier selection: Manufacturers that respond 24 hours a day to reduce equipment downtime.
lFBZhengzhou Protech Technology Co., Ltd

4. Typical laboratory application scenarioslFBZhengzhou Protech Technology Co., Ltd
Research on Photovoltaic CellslFBZhengzhou Protech Technology Co., Ltd
PERC cell: Deposition of backside Al ₂ O ∝/SiN ₓ laminated film to achieve dual functions of backside passivation and anti reflection, improving efficiency.lFBZhengzhou Protech Technology Co., Ltd
TOPCon battery: Utilizing PECVD deposition of tunneling oxide layer (SiO ₂) and doped polycrystalline silicon layer to construct efficient carrier transport channels.lFBZhengzhou Protech Technology Co., Ltd
Semiconductor device manufacturinglFBZhengzhou Protech Technology Co., Ltd
Deposition of SiO ₂ as the gate dielectric layer, adjusting the film density by controlling the RF power to reduce leakage current.lFBZhengzhou Protech Technology Co., Ltd
Case: A certain chip laboratory uses PECVD deposition of low stress SiN ₓ for MEMS device packaging, resulting in improved yield.lFBZhengzhou Protech Technology Co., Ltd
Flexible Electronics and Display TechnologylFBZhengzhou Protech Technology Co., Ltd
Deposition of transparent conductive oxide (such as ITO) on polyimide substrate to achieve flexible touch screen preparation.lFBZhengzhou Protech Technology Co., Ltd
Advantages: Low temperature process avoids substrate deformation and high film transmittance.
lFBZhengzhou Protech Technology Co., Ltd

5. Key points for equipment operation and maintenancelFBZhengzhou Protech Technology Co., Ltd
Installation and debugginglFBZhengzhou Protech Technology Co., Ltd
Strictly follow the operation manual to ensure correct electrode connection, quartz tube sealing, and vacuum pump docking.lFBZhengzhou Protech Technology Co., Ltd
Testing: Leakage rate testing and temperature control calibration are required before first use.lFBZhengzhou Protech Technology Co., Ltd
process parameters optimizationlFBZhengzhou Protech Technology Co., Ltd
Key parameters: RF power (affecting plasma density), gas flow ratio (determining film composition), temperature (controlling reaction rate).lFBZhengzhou Protech Technology Co., Ltd
Routine maintenancelFBZhengzhou Protech Technology Co., Ltd
Cleaning: Wipe the reaction chamber with a dust-free cloth after each experiment to avoid residue contamination and subsequent deposition.lFBZhengzhou Protech Technology Co., Ltd
Consumables replacement: Vacuum pump oil should be replaced every 500 hours, and quartz tube transparency should be checked every 200 experiments.
lFBZhengzhou Protech Technology Co., Ltd

Rotating tilted PECVD experimental furnace (click on the image to view product details)lFBZhengzhou Protech Technology Co., Ltd
Rotating tilted PECVD experimental furnace (click on the image to view product details)
lFBZhengzhou Protech Technology Co., Ltd

Overall, the application of chemical vapor deposition (PECVD) experimental furnaces is very extensive. However, it is important to strictly follow the user manual during use to avoid unpredictable consequences. Before customizing products, it is recommended to communicate the parameters with relevant technical personnel in order to customize PECVD experimental furnaces that are more suitable for one's own experiments!Click to learn more PECVD devices! Or click on online customer service to learn more about product information!lFBZhengzhou Protech Technology Co., Ltd

HOT PRODUCTS

  • Continuous feeding and discharging multi temperature zone large diameter rotary furnace
  • Tube type vertical lifting bell cover furnace
  • 1200 ℃ touch screen high-temperature vacuum tube furnace
  • Large vertical tube furnace with preheating

Inquiry

Please leave a message here. We will reply you in 24 hours.

live chat customer service