Atmosphere furnace furnace cleaning methodMhBZhengzhou Protech Technology Co., Ltd
Vacuum pre-vacuum method: StepsMhBZhengzhou Protech Technology Co., Ltd
1. Any outlet nozzle connected to a vacuum hose;MhBZhengzhou Protech Technology Co., Ltd
2. The furnace atmosphere furnace pre-vacuum chamber;MhBZhengzhou Protech Technology Co., Ltd
3. pass into the protective gas;MhBZhengzhou Protech Technology Co., Ltd
4.The oven cavity and then the pre-vacuum;MhBZhengzhou Protech Technology Co., Ltd
5. This cycle several times to reach the furnace atmosphere within the requirements. MhBZhengzhou Protech Technology Co., Ltd
Shielding gas substitution method:MhBZhengzhou Protech Technology Co., Ltd
1. protective gas atmosphere furnace should normally be raised before passed into the furnace;MhBZhengzhou Protech Technology Co., Ltd
2. The protective gas can be up, down, after three wash through the mouth, should vent needle valve to the maximum air out as soon as possible in order to facilitate the furnace;MhBZhengzhou Protech Technology Co., Ltd
3. General into the furnace through the furnace volume about 10 times the shielding gas, the oxygen concentration in the furnace can be reduced to about 10ppm;MhBZhengzhou Protech Technology Co., Ltd
4. When the oxygen concentration in the furnace process in line with the requirements of the product may be a vent needle off small, to save protective gas, closed mouth wash from entering the air intake through the meter;MhBZhengzhou Protech Technology Co., Ltd
5. atmosphere furnace use, must maintain a positive pressure within the chamber to prevent outside air from entering the furnace chamber;